In this study, energy and exergy analyses are conducted on a multi-generation system driven by renewable energy source. The system produces power, cooling and domestic hot water as output by means of a gas cycle, a steam cycle, a double-effect absorption chiller and two domestic hot water heaters. Parametric analysis is performed so as to examine the results of altering certain operating conditions; for example ambient temperature and irradiation from the sun on the effectiveness of the system. This solar multi-generation system is seen to have an energetic efficiency of 55.94% and an exergetic efficiency of 29.23%, while the energetic coefficient of performance of the double-effect LiBr-H2O pair absorption chiller is determined to be 1.253 and the exegetic efficiency of the absorption chiller is 0.3762. The exergy destruction assessment for some of the system components reveals that the receiver of the solar power tower is the component with the highest exergy destruction rate.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.