Abstract

Abstract Energy and exergy studies were conducted in an orange juice manufacturing industry in Nigeria to determine the energy consumption pattern and methods of energy optimization in the company. An adaptation of the process analysis method of energy accounting was used to evaluate the energy requirement for each of the eight defined unit operations. The types of energy used in the manufacturing of orange juice were electrical, steam and manual with the respective proportions of 18.51%, 80.91% and 0.58% of the total energy. It was estimated that an average energy intensity of 1.12 MJ/kg was required for the manufacturing of orange juice. The most energy intensive operation was identified as the pasteurizer followed by packaging unit with energy intensities of 0.932 and 0.119 MJ/kg, respectively. The exergy analysis revealed that the pasteurizer was responsible for most of the inefficiency (over 90%) followed by packaging (6.60%). It was suggested that the capacity of the pasteurizer be increased to reduce the level of inefficiency of the plant. The suggestion has been limited to equipment modification rather than process alteration, which constitutes additional investment cost and may not be economical from an energy savings perspective.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call