Abstract
The stray load losses (SLLs) in electrical machines represent a nonnegligible contribution of the total losses and a key point for an accurate evaluation of the energy efficiency of considered device. In this paper, one aspect of these SLLs, the end-region leakage fluxes and losses, is investigated and considered for the case of a high-power cage induction motor. The study is performed at locked rotor, no-load, and rated load conditions using a 3-D finite-element modeling approach. The influence of the leakage flux on the end-region conductive parts of the motor is analyzed together with the eddy current loss calculation. Finally, the SLLs are calculated and compared with the experimental measurements based on the IEEE standard 112-method B test.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.