Abstract

To describe the efficacy and value of endovascular stent-grafts for the treatment of aortic anastomotic pseudoaneurysms. Three patients with proximal aortic anastomotic pseudoaneurysms 8--15 years after prosthetic reconstruction were treated by transfemoral stent-graft implantation. In two patients the pseudoaneurysms were excluded by Talent prostheses [tube graft (n = 1), bifurcated graft (n = 1)]. In one patient an uniiliac Zenith stent-graft was implanted and an extra-anatomic crossover bypass for revascularization of the contralateral lower extremity was performed. All procedures were successful with primary exclusion of the pseudoaneurysms. During the follow-up (mean 16 months) one endoleak occurred due to migration of the tube stent-graft. The endoleak was sealed successfully by implanting an additional bifurcated stent-graft. Stent-graft exclusion of aortic pseudoaneurysms offers a minimally invasive and safe alternative to open surgical reconstruction.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.