Abstract
Isolated common iliac artery aneurysm is a rare condition that is treated aggressively because of its high risk of rupture. Endovascular abdominal aortic aneurysm (AAA) repair has recently been extended to the clinical management of the iliac artery aneurysm. Stent grafts have been used successfully to exclude iliac artery aneurysms. Successful graft deployment and aneurysm exclusion require adequate seal and fixation at the proximal and distal attachment sites. This article presents a high-risk surgical patient whose 6.8-cm-diameter iliac artery aneurysm was repaired with a Zenith AAA Endovascular Graft Converter (Cook, Bloomington, Indiana). This device is normally used to convert an aortobiiliac endograft to an aortouniiliac endograft during AAA repair. The tapered 80-mm-long graft has diameters of 24 mm proximally and 12 mm distally. Completion arteriogram demonstrated exclusion of the iliac artery aneurysm with no evidence of endoleak. No postoperative complications occurred. No endoleak was seen on the follow-up abdominal computed tomography scan.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.