Abstract

Four plan-do-study-act (PDSA) cycles were completed in the operating rooms at Nationwide Children's Hospital over 9 months to assess ways to improve the accuracy of obtaining recommended ETT cuff pressures. Control charts were used to evaluate the primary outcome measure. Preimplementation, ETT cuff pressures were out of the recommended range 76% of the time. Cuff pressures were out of the recommended range 64% of the time with the addition of the air method, 84% of the time in the tidal volume ratio cycle, and 50% of the time using the removal of air technique. The removal of air method was the most effective in achieving cuff pressures within the recommended pressure range (P < 0.001). Using quality improvement methodology, the percentage of ETT cuff pressures falling within the recommended pressure range increased using the removal of air technique. This approach is a simple and practical method that can be easily implemented in the clinical setting and would provide additional safety in the anesthetic management of pediatric patients.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.