Abstract

Two cases of difficult ventilation are presented, the first caused by endotracheal tube obstruction with nasal turbinate, and the second caused by tracheobronchial obstruction with blood clots. The clinical presentation in each case was characterized by extreme difficulty in ventilating and severe hypercapnia despite vigorous ventilatory efforts with either a mechanical ventilator or resuscitator bag. A simple manipulation of the endotracheal tube cuff helped to differentiate between increased impedance caused by endotracheal tube obstruction as opposed to increased respiratory system impedance beyond the tip of tube. In the second patient, in whom even a short interruption of ventilation was poorly tolerated, simultaneous rigid bronchoscopy (for removal of intratracheal masses) and ventilation via endotracheal tube were successfully performed.