Abstract

1. Endotoxins as components of organic dust may have adverse effects on the respiratory health of workers in poultry buildings. The move towards more welfare-friendly housing systems for layers may increase worker exposure to air contaminants due to the use of litter. 2. The endotoxin concentrations in the inhalable fraction of airborne dust (below 100 µm) from cage and alternative system houses (on-floor, free range and aviaries) were compared under both experimental and commercial conditions. 3. The endotoxin concentration was higher in experimental aviaries (median: 565 EU/m3, range: 362-1491 EU/m3) than in cage housing (98 EU/m3 (51-470)). 4. In field conditions, the endotoxin concentration in the air of 13 alternative houses was higher (35 to 3156 EU/m3) than in cage system buildings (n = 8, 78-576 EU/m3). It was correlated to the respirable dust concentration (fraction below 5 µm) and to the temperature inside the hen house but no seasonal variation was observed. 5. The present study emphasises that considerable worker exposure to endotoxins may occur in laying houses, especially in alternative systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.