Abstract

BackgroundEndotoxin induces an inflammatory response, with secondary release of cytokines, which can progress to shock and multiple organ failure. We explored whether continuous renal replacement therapy (CRRT) using a modified membrane (oXiris) capable of adsorption could reduce endotoxin and cytokine levels in septic patients.MethodsSixteen patients requiring CRRT for septic shock-associated acute renal failure and who had endotoxin levels >0.03 EU/ml were prospectively randomized in a crossover double-blind design to receive CRRT with an oXiris filter or with a standard filter. Endotoxin and cytokine levels were measured at baseline and 1, 3, 8, 16 and 24 hours after the start of CRRT. Norepinephrine infusion rate and blood lactate levels were monitored.ResultsDuring the first filter treatment period, endotoxin levels decreased in 7 of 9 (77.8%) oXiris filter patients, but in only 1 of 6 (16.7%) standard filter patients (P = 0.02). Levels of tumor necrosis factor (TNF)-α, interleukin (IL)-6, IL-8 and interferon (IFN)γ decreased more with the oXiris filter than with the standard filter. Lactate concentration decreased with oXiris (-1.3[-2.2 to -1.1] mmol/l, P = 0.02), but not with the standard filter (+0.15[-0.95 to 0.6]). The norepinephrine infusion rate was reduced during oXiris CRRT, but not during standard filter CRRT. In the second filter treatment period, there was no significant reduction in endotoxin or cytokine levels in either group.ConclusionsCRRT with the oXiris filter seemed to allow effective removal of endotoxin and TNF-α, IL-6, IL-8 and IFNγ in patients with septic shock-associated acute renal failure. This may be associated with beneficial hemodynamic effects.

Highlights

  • Endotoxin induces an inflammatory response, with secondary release of cytokines, which can progress to shock and multiple organ failure

  • We explored whether continuous renal replacement therapy (CRRT) using a modified membrane capable of adsorption could reduce endotoxin and cytokine levels in septic patients

  • During the first filter treatment period, endotoxin levels decreased in 7 of 9 (77.8%) oXiris filter patients, but in only 1 of 6 (16.7%) standard filter patients (P = 0.02)

Read more

Summary

Objectives

The aim of this study was to evaluate the ability of the oXiris dialysis filter membrane to reduce endotoxin and cytokine levels during a 24-hour treatment period in patients with septic shock, and to compare the results with those obtained using a standard filter

Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call