Abstract
Endothelin-1 (ET-1) is a potent vasoconstrictive polypeptide produced from vascular endothelial cells. The effects of ischaemia, reperfusion, and exsanguination on plasma ET-1 levels were studied and compared in the mongrel dog after infrarenal aortic cross clamping. Ischaemia produced a trend toward increased ET-1 serum levels (p < 0.07 with Bonferroni correction) that did not reach significance. Plasma ET-1 levels were significantly increased during reperfusion and even further elevations were found following exsanguination. We found a 2-3 fold increase in ET-1 levels following reperfusion (Initial 3.19 +/- 0.27 pg/ml vs. Reperfusion maximum 6.32 +/- 0.72 pg/ml, Bonferroni p < 0.01). Haemorrhagic shock was associated with a 3-4 fold increase in ET-1 levels (Initial 3.19 +/- 0.27 pg/ml vs. Exsanguination maximum 8.37 +/- 0.97 pg/ml Bonferroni p < 0.001). These data reveal that ET-1 is released during reperfusion and exsanguination and may mediate remote vascular events associated with infrarenal aortic cross clamping and acute blood loss.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.