Abstract

Forehead augmentation have become popular aesthetic procedures among Asians in recent years. However, the use of polyetheretherketone (PEEK) patient-specific implant (PSI) in the facial contouring surgery for aesthetic considerations is not well documented in the existing studies. The purpose of this study was to develop a novel method for forehead augmentation and assess the clinical outcomes and complications in patients who underwent forehead augmentation with PEEK PSI assisted by endoscopy. The PEEK PSIs were fabricated using the virtual surgical planning (VSP) and the computer-aided manufacturing (CAM) for each patient, preoperatively. The implant pockets were dissected in the subperiosteal plane, and PEEK PSIs were placed in their designed position and fixed assisting by endoscopy via small incision within the hairline. All patients were asked to complete the FACE-Q questionnaire before and 6 months after the operation. Pre- and postoperative demographics, photographs, and other clinical data of patients were collected and analyzed. 11 patients underwent forehead augmentation were enrolled in this study. All procedures were completed successfully with the help of endoscope. The average patient age was 30.63 ± 2.54years. The mean thickness and size of PEEK PSI were 4.44 ± 1.77mm and 38.43 ± 22.66cm2, respectively. The mean operative time was 83.00 ± 29.44min, and the mean postoperative follow-up period was 11.00 ± 6.50months. No implant exposure, extrusion or removal were reported. The FACE-Q scores of patients in satisfaction with the forehead increased from 47.64 ± 7.15 to 78.81 ± 6.35. PEEK PSIs can be prefabricated to achieve accurate remodeling of the frontal contour with good esthetic outcomes. The endoscope provides direct and magnified vision, which allow easy access to the supraorbital rim and lateral edge of the eyebrow arch and confirming the position of the implants without damaging nerves and vessels. Endoscopic-assisted forehead augmentation with PEEK PSI is safe and effective. This journal requires that authors assign a level of evidence to each article. For a full description of these evidence-based medicine ratings, please refer to the Table of contents or the online Instructions to Authors www.springer.com/00266 .

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.