Abstract

To assess the ability of endoscopic ultrasonography (EUS) to differentiate neoplastic from non-neoplastic polypoid lesions of the gallbladder (PLGs). The uses of EUS and transabdominal ultrasonography (US) were retrospectively analyzed in 94 surgical cases of gallbladder polyps less than 20 mm in diameter. The prevalence of neoplastic lesions with a diameter of 5-10 mm was 17.2% (10/58); 11-15 mm, 15.4% (4/26), and 16-20 mm, 50% (5/10). The overall diagnostic accuracies of EUS and US for small PLGs were 80.9% and 63.9% (P < 0.05), respectively. EUS correctly distinguished 12 (63.2%) of 19 neoplastic PLGs but was less accurate for polyps less than 1.0 cm (4/10, 40%) than for polyps greater than 1.0 cm (8/9, 88.9%) (P = 0.02). Although EUS was more accurate than US, its accuracy for differentiating neoplastic from non-neoplastic PLGs less than 1.0 cm was low. Thus, EUS alone is not sufficient for determining a treatment strategy for PLGs of less than 1.0 cm.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.