Abstract

Intestinal transplant (ITx) rejection lacks a reliable noninvasive biomarker and rejection surveillance relies on serial endoscopies and mucosal biopsies followed by histologic assessment. Endoscopic biopsies are also essential for identifying other ITx-related complications such as infectious, allergic, and inflammatory graft enteritis as well as post-transplant lymphoproliferative disease or graft versus host disease. In spite of its central role in ITx, published guidelines on endoscopy and biopsy are lacking and significant variability between centers in terms of timing and technical performance exists. Therefore, an international expert group convened and discussed several aspects related to the surveillance endoscopy after ITx with the aim to summarize and standardize its practice. This article summarizes these considerations on endoscopic ITx monitoring and highlights practices of surveillance and for-cause endoscopy, biopsy techniques, pathologic evaluation, potential risks and complications, outsourcing, and less-invasive monitoring techniques.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.