Abstract

AIMTo evaluate the efficacy and safety of endoscopic submucosal dissection (ESD) using the clutch cutter (CC) (ESD-CC) for gastric adenoma (GA).METHODSFrom June 2007 to August 2015, 122 consecutive patients with histological diagnoses of GA from specimens resected by ESD-CC were enrolled in this prospective study. The CC was used for all ESD steps (marking, mucosal incision, submucosal dissection, and hemostatic treatment), and its therapeutic efficacy and safety were assessed.RESULTSBoth the en-bloc resection rate and the R0 resection rate were 100% (122/122). The mean surgical time was 77.4 min, but the time varied significantly according to tumor size and location. No patients suffered perforation. Post-ESD-CC bleeding occurred in six cases (4.9%) that were successfully resolved by endoscopic hemostatic treatment.CONCLUSIONESD-CC is a technically efficient, safe, and easy method for resecting GA.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.