Abstract
To evaluate the efficacy and safety of novel plasma radio frequency generator and its single-use polypectomy snares for endoscopic mucosal resection (EMR) of gastrointestinal (GI) polyps. A total of 217 patients with 413 GI polyps were recruited from four centers in China. Patients were assigned to experimental or control groups using a central randomization method. The experimental group used the novel plasma radio frequency generator and its matched single-use polypectomy snares (Neowing, Shanghai), while the control group used the high-frequency electrosurgical unit (Erbe, Germany) and disposable electrosurgical snares (Olympus, Japan). The primary endpoint was the en bloc resection rate, and the non-inferiority margin was set at 10%. Secondary endpoint included operation time, coagulation success rate, intraoperative and postoperative bleeding rate, and perforation rate. The en bloc resection rate was 97.20% (104/107) in the experimental group and 95.45% (105/110) in the control group (P = 0.496). The operation time was 29.14 ± 20.21min in the experimental group and 30.26 ± 18.74min in the control group (P = 0.671). The average removal time of a single polyp in the experimental group was 7.52 ± 4.45min, which was slightly shorter than that in the control group 8.90 ± 6.67min, with no statistical difference (P = 0.076). The intraoperative bleeding rates of the experimental group and control group were 8.41% (9/107) and 10.00% (11/110), respectively (P = 0.686). No intraoperative perforation occurred in either group. The postoperative bleeding rates of the experimental group and the control group were 1.87% (2/107) and 4.55% (5/110), respectively (P = 0.465). No postoperative perforation occurred in the experimental group (0/107), while one case of delayed perforation occurred in the control group (1/110, 0.91%). There was no statistical difference between the two groups. Endoscopic mucosal resection of GI polyps with the novel plasma radio frequency generator is safe and effective, and non-inferior to the conventional high-frequency electrosurgical system.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.