Abstract

We report a rare case of a secondary aortoesophageal fistula discovered incidentally during elective upper endoscopy. The patient had previously undergone repair of a descending thoracic aortic aneurysm with a Dacron interposition graft. Esophagoscopy 2 months after the aneurysm repair demonstrated a large mid-esophageal erosion with visualization of the aortic graft at the base. The aortoesophageal fistula had been clinically silent to this point. During preparation for surgery the patient developed large-volume esophageal hemorrhage and died following attempted endovascular repair of the fistula. A review of the literature on the diagnosis and surgical management of aortoesophageal fistula is presented.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.