Endoscopic and radiographic techniques have not been widely applicable in the evaluation of chemically induced murine colon cancer. The authors investigated methods of cleansing the rat colon and refined endoscopic and radiographic techniques. They compared total colonoscopy (TC) and air-contrast (ACBE) and single-contrast barium enema (SCBE) findings with those obtained at necropsy in rats with 1,2-dimethylhydrazine (DMH)-induced colon cancer. Gastrograffin enemas with bisacodyl suppositiories showed complete evacuation of solid feces. Sprague-Dawley rats treated with DMH had their colons cleansed and then underwent TC (5.0-mm Olympus bronchoscope) and either SCBE or ACBE. Colonoscopy and ACBE were equally sensitive (81.5% and 76.3%, respectively), although SCBE was significantly insensitive in identifying lesions (P less than 0.001). This study demonstrates that: (1) mechanical cleansing of the rat colon is feasible, (2) TC and barium radiology can be done routinely after mechanical cleansing, and (3) TC and double-contrast BE are sensitive in identifying colon lesions. These techniques will provide a means for manipulation of murine tumors and in vivo surveillance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.