Abstract
An endometrial biopsy allows for a comprehensive assessment of the uterine environment of a breeding female. Although routine in mares, devices used for endometrial biopsies are impracticable in heifers due to the size and structure of the cervix. This report describes the use of a human bronchoscopy biopsy device (Karl Storz® 10366L) for collection of endometrial biopsies in Bos indicus beef heifers. The Storz® device is smaller and thinner and enabled the collection of an endometrial biopsy in 86% of heifers (n=44/51). The biopsied tissue was of good quality and suitable for transcriptomic assessment of the endometrium, with total RNA yield and RNA integrity number (RIN) averaging 1.3μg (range 0.4-5.3μg) and 7.4 (range 5.7-8.4), respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.