Abstract

BackgroundAt present only few studies directly compare the diagnostic yield of endobronchial ultrasound guided fine needle aspiration (EBUS-FNA) and transcervical video-assisted mediastinoscopy (TM) for mediastinal lymph node staging in patients with NSCLC. If and when EBUS-FNA may replace TM as Gold Standard remains controversial.MethodsFrom April 2008 to December 2009, 36 patients with mediastinal lymphadenopathy underwent simultaneous EBUS-FNA/ TM at our institution. Among them were 26 patients with confirmed or suspected NSCLC.ResultsA total of 133 samples were obtained by EBUS-FNA and 157 samples by TM. EBUS-FNA achieved significantly less conclusive, but more indeterminate pathological results in comparison to TM (78.7% vs. 98.6%, p < 0.001; 14.9% vs. 1.4%, p = 0.007). Less paratracheal nodes were sampled by EBUS-FNA (right: 46.2% vs. 88.5%, p = 0.003; left: 23.1% vs. 65.4%, p = 0.005), while sampling rates in the subcarinal localisation were comparable (96.2% vs. 80.8%, p = NS). Among patients with confirmed NSCLC and conclusive EBUS-FNA/ TM findings (n = 18), the prevalence of N2/N3 disease was 66.7% (n = 12) according to TM findings. Diverging nodal stages were found in five patients (27.8%). Three patients who were N2 negative in EBUS-FNA were upstaged to N2 or N3 by TM, two patients with N2 status in EBUS-FNA were upstaged to N3 by TM.ConclusionsCompared to TM, EBUS-FNA had a lower diagnostic yield and resulted in systematic mediastinal nodal understaging. At this point we suggest corroborating negative EBUS-FNA results by transcervical mediastinoscopy.

Highlights

  • At present only few studies directly compare the diagnostic yield of endobronchial ultrasound guided fine needle aspiration (EBUS-FNA) and transcervical video-assisted mediastinoscopy (TM) for mediastinal lymph node staging in patients with Non small cell lung cancer (NSCLC)

  • Non-representative samples were only found in EBUS-FNA (n = 3)

  • In the present study, EBUS-FNA and TM were directly compared for mediastinal nodal assessment in patients with proven or suspected NSCLC

Read more

Summary

Introduction

At present only few studies directly compare the diagnostic yield of endobronchial ultrasound guided fine needle aspiration (EBUS-FNA) and transcervical video-assisted mediastinoscopy (TM) for mediastinal lymph node staging in patients with NSCLC. If and when EBUS-FNA may replace TM as Gold Standard remains controversial. Though transcervical mediastinoscopy (TM) remains the gold standard for Hitherto, it is still controversial if and when EBUSFNA may replace TM as gold standard in mediastinal nodal assessment prior to curative lung resection. Very few published studies directly compare the diagnostic value of EBUS-FNA and TM in this regard. We launched a prospective trial set to compare the diagnostic value of EBUS-FNA and TM for mediastinal nodal staging in patients with confirmed or suspected NSCLC by performing both procedures concomitantly While certain groups report lower sensitivity and similar specificity of EBUS-FNA [8], other postulate higher sensitivity and negative predictive value of EBUS-FNA [9].

Methods
Results
Discussion
Conclusion