Abstract

The design of the Belle endcap calorimeter based on pure CsI is presented. The suggested calorimeter consists of pure CsI crystals with readout by vacuum photopentodes followed by the analysis of the shape of the output signal. The results of tests of the counters are presented. Photopentodes provide a gain factor about 150–200 without magnetic field. Tests with magnetic field show that the gain factor drops down about 3.5 times in axial magnetic field of 1.5T. The preamplifier-shaper has been developed which provides electronics noise of 1000 photoelectrons. The beam test results showed the energy resolution about 2.2% for 100MeV photons and time resolution better than 2ns. Radiation hardness tests of the counters have been carried out.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.