The End Station Refrigerator 2 (ESR2) cryoplant will provide cryogens to three of the four experimental halls in support of 12 GeV Continuous Electron Beam Accelerator Facility (CEBAF) experimental demands. In particular, the near-future Measurement of a Lepton-Lepton Electroweak Reaction (MOLLER) experiment requires the additional capacity provided by ESR2. This new cryoplant consists of a 4.0 kW at 4.5-Kelvin cold box and a two-stage compressor system. The cold box and compressor equipment were received from the Superconducting Super Collider (SSC) project and are being refurbished to meet Jefferson Lab’s future operating needs. The ESR2 cryoplant includes a new, 50+ m long cold transfer line, bayonet-can, utility system, and control system. The paper describes the fabrication and installation challenges faced, mitigations adopted, and future work plans for the cryoplant.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.