Abstract
An open-ended microwave oven system is presented and characterized for the rapid encapsulation of microelectronic components. In situ real-time measurement of the temperature of the curing materials is carried out by an infrared pyrometer integrated in the microwave head of the oven. An automatic computer-controlled closed feedback loop has been used to measure the temperature in the curing material and modulate the system operating power to obtain predefined curing temperature cycles for efficient curing. Uniform curing of the encapsulant material is achieved with typical cure time of ~300s with a ramp rate of 1.66°C/s and a hold period of ~100s . Differential scanning calorimeter based measurement for the curing of the polymer dielectric indicates a near 100% degree of cure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Components, Packaging and Manufacturing Technology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.