Abstract

A group of DPP-4 inhibitors such as alogliptin, linagliptin and saxagliptin were selected for enantioseparation for this study. Crown ether columns contain a chiral crown ether ring as a chiral selector is suitable for the compounds having primary amino groups. Since the selected compounds contain free amino groups, a crown ether column was selected for enantiomeric separation of dipeptidyl peptidase-4 inhibitors. Dipeptidyl peptidase-4 inhibitors are a class of oral hypoglycemics that block dipeptidyl peptidase-4 enzyme and can be used to treat diabetes mellitus type 2. A sensitive HPLC method was developed to separate the enantiomers of each dipeptidyl peptidase-4 inhibitor. Effects of various parameters such as type of solvents, selection of additives, effect of pH and column temperature on chromatographic results were studied. The optimal conditions for the chiral separation of dipeptidyl peptidase-4 inhibitors without any derivatization were investigated.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call