Abstract
A method for the quantitative enantioselective analysis of amphetamine in human plasma by gas chromatography/negative ion chemical ionization mass spectrometry (GC/NICI-MS) is presented. Five-fold deuterated analogues of both enantiomers were used as internal standard. Plasma sample preparation was performed by a rapid liquid-liquid extraction using n-hexane. Derivatization with (S)-(-)-N-(heptafluorobutyryl)prolyl chloride was accomplished directly in the n-hexane extract to avoid loss of amphetamine during sample concentration. The method was validated in the expected concentration range of 0.006 for a pharmacokinetic study. Calibration curves were linear within a range 0.006-50 ng/mL plasma. Precision and accuracy were acceptable over the entire calibration range. Baseline separation of the enantiomers was easily achieved on a 15-m nonchiral apolar column. The method is simple and robust, and has been applied to the batch analysis of amphetamine enantiomers.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.