Abstract

A method for the quantitative enantioselective analysis of amphetamine in human plasma by gas chromatography/negative ion chemical ionization mass spectrometry (GC/NICI-MS) is presented. Five-fold deuterated analogues of both enantiomers were used as internal standard. Plasma sample preparation was performed by a rapid liquid-liquid extraction using n-hexane. Derivatization with (S)-(-)-N-(heptafluorobutyryl)prolyl chloride was accomplished directly in the n-hexane extract to avoid loss of amphetamine during sample concentration. The method was validated in the expected concentration range of 0.006 for a pharmacokinetic study. Calibration curves were linear within a range 0.006-50 ng/mL plasma. Precision and accuracy were acceptable over the entire calibration range. Baseline separation of the enantiomers was easily achieved on a 15-m nonchiral apolar column. The method is simple and robust, and has been applied to the batch analysis of amphetamine enantiomers.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.