Abstract

Commercial D,L-kynurenine was resolved by high-speed countercurrent chromatography using a cross-axis coil planet centrifuge. The separation was performed with an aqueous-aqueous polymer phase system composed of 10% (w/w) polyethylene glycol 8000 and 5% (w/w) dibasic sodium phosphate containing 6% (w/w) bovine serum albumin as a chiral selector. The lower phosphate-rich mobile phase eluted the L-enantiomer first followed by the D-enantiomer. The peak resolution was 0.94 for 2.5 mg of the sample. The separation was completed within 3.5 h.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.