Abstract

ABSTRACTThe enantiomeric separation of a novel series of twenty-eight racemic mixtures of citalopram analogues was performed by high performance liquid chromatography (HPLC). Due to the effectiveness of citalopram as an antidepressant drug, the development of new compounds based on its chemical structure is interesting, and their enantiomeric separation is needed to allow further pharmacokinetic studies. Several bonded cyclodextrin (both native and derivatized) and macrocyclic glycopeptide based chiral stationary phases (CSPs) were evaluated for their ability to separate this set of compounds via HPLC. Polar ionic, polar organic, and reversed phase modes were tested. Twenty-five of the racemic mixtures were separated with resolutions and enantiomeric selectivities up to 2.9 and 1.33, respectively. A total of eighteen baseline separations were achieved, while seven compounds were partially separated. Vancomycin based columns operated in the polar ionic mode resulted in the greatest number of separations. Lastly, the chromatographic behaviors of similar compounds were compared based on their chemical structure and also on the chiral selectors used.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.