Abstract

Abstract Enantiomeric purity (EP) is an important value which denotes the relative percentage of the L-isomer with respect to the D-isomer. For 11C and 18F-labelled amino acid (AA) radiopharmaceutical (RP) production, EP represents a quality control parameter specified in European and national monographs for particular RPs. In most instances, EP value of greater then 90 or 95% (depending on AA type) is required as part of the quality control (QC) value of a RP following radiosynthesis. In common practice, two chromatographic columns are used for the EP determination of RPs: Crownpak CR(+) (Daicel), which contains a crown ether stationary phase or Chirobiotic T (Astec), which contains silica-bound glycoproteins as the stationary phase. The application of column Crownpak CR(+) requires that only perchloric acid solution (with pH 1–2) may be used, as the retention capability of the stationary phase is greatly reduced using organic solvents. This work intends to identify which chromatographic system is more accurate and reliable for EP determination as part of QC. We performed a series of parallel injections of the same batch of the widely used AA RPs [11C]MET and [18F]FET on the two aforementioned columns. The EP determination using column Crownpak CR(+) consistently provided a lower EP value compared to the Chirobiotic T column; the EP deviation between the respective columns was found to range from 2.4–4.0% for the same RP sample. Furthermore, the EP value was influenced by a sample’s dilution factor, e.g. the EP was observed to increase up to 1.5% when the radioactive sample had a fivefold dilution factor. This phenomenon was consistent for both Crownpak CR(+) and Chirobiotic T columns. Finally, a series of standard solutions of non-radioactive methionine with various ratios of L-and D-isomers was analyzed. The data obtained for non-radioactive methionine confirmed that column Crownpak CR(+) incorrectly provided a higher D-enantiomer concentration, whereas Chirobiotic T was found to provide a lower D-enantiomer concentration of the same sample. The deviation from the theoretical EP value was between 0.67 and 1.92%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.