Abstract

Methods The current study includes 80 extracted premolars of human from the patient visiting for orthodontic treatment of Coorg Institute of Dental Sciences, Karnataka, India. The brackets were debonded using four different methods. The enamel surface damage after the procedure was assessed with the Enamel Surface Index (ESI); similarly, the Adhesive Remnant Index (ARI) score was used to determine the adhesive residual deposit. Scanning electron microscopy (SEM) was used to visualize better microporosities and micromechanical retention of adhesive remnants on the enamel surface. The normality of the data was tested using the Kolmogorov–Smirnov test. Depending upon the normality test result, the one-way ANOVA test or Kruskal–Wallis test was used to test the mean ESI and mean ARI differences among different debonding methods along with the appropriate post hoc tests. The necessary ethical clearance was obtained from the Ethics Committee of the institute. Results The ultrasonic scaler (US) technique led to more significant enamel surface damage, with 13 (65%) samples in the ESI scores III and IV against the satisfactory surface in 2 (10%) samples with the ligature cutter (LC) technique (ESI-I) reflecting LC as a better technique. The ESI scores (III and IV) for debonding plier (DP) and thermal method (TM) reflected a higher value in 12 (60%) and 10 (50%) samples and caused more damage to the enamel surface as compared to the LC technique. The ARI score was highest (ARI-1 = 40%) with the LC technique, followed by the US (ARI-1 = 20%), TM (ARI-1 = 15%), and DP (ARI-1 = 5%) methods. We have observed a significant association (p value <0.05) of the ARI score among four different debonding ways in terms of each tooth's residual adhesive after the bracket removal. Conclusion The result establishes the LC technique as a more acceptable one as it causes minimal harm to the debonded surface. The adhesive left on the debonded area is also minimum as compared to the other three methods tested. Therefore, it can be suggested as an ideal method.

Highlights

  • A beautiful smile to every patient is the expectation for each orthodontic professional after the debonding procedures

  • The enamel surface damage is low with more satisfactory surfaces with the ligature cutter (LC) method (ESI-I) containing 10%

  • Adhesive Remnant Index (ARI) score to determine each tooth’s residual adhesive after bracket removal following four different debonding methods reveals a significant association between ARI and the four different debonding techniques (p value

Read more

Summary

Introduction

A beautiful smile to every patient is the expectation for each orthodontic professional after the debonding procedures. E primary responsibility of an orthodontist is to preserve the dental enamel structure during debonding ceramic brackets. E brackets were debonded using four different methods. Depending upon the normality test result, the one-way ANOVA test or Kruskal–Wallis test was used to test the mean ESI and mean ARI differences among different debonding methods along with the appropriate post hoc tests. E ESI scores (III and IV) for debonding plier (DP) and thermal method (TM) reflected a higher value in 12 (60%) and 10 (50%) samples and caused more damage to the enamel surface as compared to the LC technique. We have observed a significant association (p value

Objectives
Results
Discussion
Conclusion