Abstract

The aim of this in vitro study was to compare the shear bond strength (SBS) and Adhesive Remnant Index (ARI) scores of two self-etching no-mix adhesives (Prompt L-Pop™ and Scotchbond™) for orthodontic appliances to the commonly used total etch system Transbond XT™ (in combination with phosphoric acid). In all, 60human premolars were randomly divided into three groups of 20specimens each. In group 1 (control), brackets were bonded with Transbond™ XT primer. Prompt L-Pop™ (group 2) and Scotchbond™ Universal (group 3) were used in the experimental groups. Lower premolar brackets were bonded by light curing the adhesive. After 24h of storage, the shear bond strength (SBS) was measured using a Zwicki 1120 testing machine. The adhesive remnant index (ARI) was determined under 10× magnification. The Kruskal-Wallis test was used to statistically compare the SBS and the ARI scores. No significant differences in the SBS between any of the experimental groups were detected (group 1: 15.49±3.28MPa; group 2: 13.89±4.95MPa; group 3: 14.35±3.56MPa; p=0.489), nor were there any significant differences in the ARI scores (p=0.368). Using the two self-etching no-mix adhesives (Prompt L-Pop™ and Scotchbond™) for orthodontic appliances does not affect either the SBS or ARI scores in comparison with the commonly used total-etch system Transbond™ XT. In addition, Scotchbond™ Universal supports bonding on all types of surfaces (enamel, metal, composite, and porcelain) with no need for additional primers. It might therefore be helpful for simplifying bonding in orthodontic procedures.