Abstract
AbstractThis paper addresses the implementation of second‐moment closure into a collocated variable arrangement body‐fitted‐finite‐volume scheme in which Cartesian velocity components are used. The methods for avoiding instability in the solution procedure are described. A new method for the treatment of the near‐wall regions for the momentum equations, as well as the prescription of the stresses at the wall, is described in detail. The performance of the methodology is assessed by applying it to two flow situations, where experimental data are available: the flow over a backward step, and the flow through a sinusoidal pipe constriction. The results are very promising.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal for Numerical Methods in Fluids
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.