Abstract
An effective biosensing platform is described based on halloysite nanotube/carbon composite decorated with Pd nanoparticles (HNT/C@Pd NPs). A novel electrochemical aptasensor was designed using the proposed nano-platform to determine human epidermal growth factor receptor 2 (HER2), a breast cancer biomarker. Inherently, aptasensing interfaces provide high sensitivity and selectivity for tumor markers owing to the high specific surface area of HNT/C and good conductivity stems from deposition of Pd NPs into HNT/C composite. With a correlation coefficient of 0.996, the electrochemical aptasensor demonstrated a wide linear range from 0.03 ng/mL to 9 ng/mL. The limit of detection (LOD) of the established assay was 8 pg/mL based on S/N = 3 method. Further, the designed biosensor demonstrated acceptable selectivity, good reproducibility, and high stability. The applicability of the impedimetric sensor in human serum samples was also examined and compared to enzyme-linked immunosorbent assay (ELISA) assay (p-value >0.05). Based on the results, it was found that the proposed methodology can be used in quantification of breast cancer markers for early diagnosis and treatment.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.