Abstract

A discharge-type fusion neutron source generates neutrons by fusion reactions of hydrogen isotope atoms. In order to operate the fusion device based on the deuterium–tritium (D–T) fusion reaction, the tritium inventory is required to be decreased. In the present work, a self-sufficient system was installed into the fusion device for reducing the amount of hydrogen isotope fuel gas. The fuel gas was supplied and recovered with an intermetallic compound ZrCo in a sealed chamber in this system. A deuterium–deuterium operation was maintained for more than 60 min with stable discharge voltages, and the temperature of the ZrCo bed was changed to improve the neutron production rate. Factors that influenced the pressure inside the chamber were determined and optimized. Gas analysis using a quadrupole mass spectrometer indicates a dilution of the deuterium fuel was caused by hydrogen isotope exchange between the supplied deuterium gas and the absorbed protium on the chamber and electrodes surface. This system's hydrogen isotope control method and the amount of fuel were proposed for a D–T operation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.