Abstract

In this article, a new model to predict the amplitude reduction of the interference harmonics in power supplies with parallel topology is presented when the switching frequency modulation with variable delay (VDFM) technique is applied. The VDFM method consists of combining the interleaving and switching frequency modulation (SFM) techniques. The new model presented has been evaluated in a multichannel buck converter, operating with different numbers of converters when a triangular modulation profile is used. Theoretical study and experimental results show the influence of the number of converters and the modulation parameters with regard to electromagnetic interference reduction. From the new model presented, it is possible to predict the value of modulation parameters and the numbers of converters in order to satisfy the required attenuation regarding the electromagnetic compatibility directives, when a triangular modulation profile is used.