Abstract

The EMI performance of a non-isolated bidirectional switched-capacitor (SC) converter with quasi-resonant (QR) zero current switching (ZCS) converter is proposed in this paper. The quasi-resonant switched-capacitor converter presents low conducted EMI noise due to the sinusoidal resonant current advantages. Theoretical analysis and EMI measurement for the proposed bi-directional power conversion scheme is performed using a detailed equivalent circuit model and field test, respectively. The conducted common-mode (CM) and differential-mode (DM) noises could be separated using a power combiner from the converter circuit noises. Experimental verification is carried out to verify and compare the proposed QR ZCS SC bi-directional converter EMI performance with the conventional hard-switching device. Peak level EMI emissions in the measured frequency spectrums show the proposed device can significantly reduce from 1.5-14.3 dBμV compared with that measured in the converter without QR ZCS for the forward and reverse power flow control schemes at a specified frequency range. The radiated emissions are improved as well. It can also be observed from the CM/DM separated measurement experimental results that the DM noises are dominant. This may present better EMI suppression when designing the power line filter.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call