Abstract

This paper applied emergy analysis to the systematic evaluation of a CHP plant EIP. Considering both material circulation and energy cascade utilization and clean energy technology of CHP plant EIP, modified emergy indices for CHP plant EIP were presented. Three representative of CHP plant EIP, as cases study, were accounted. They were pulverized coal-fired CHP plant EIP, coal-fired Pressurized Fluidized Bed Combustion Combined Cycle (PFBC-CC) plant EIP and coal-fired Integrated Gasification Combined-Cycle (IGCC) plant EIP, respectively. The emergy sustainable index of the IGCC plant EIP is found to be 6.44, PFBC-CC plant EIP is found to be 4.88, pulverized coal-fired CHP plant EIP is found to be 1.39.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.