Abstract

Pre-made modular units permit rapid and economical construction and are increasingly used where repetitive units are required. The assembled building must behave as a single structure to effectively transfer the forces and moments developed by gravity and lateral loads. For this, individual modular units must be properly connected to each other. Therefore, evaluation of the behavior of connections used in modular construction is crucial. This study proposes an embedded steel column-to-foundation connection for modular structural systems and evaluates the behavior of the proposed connection. Experiments were performed to investigate the effect of the column embedment depth, the shape of the column end plate, and shear studs in the embedded region of the column on the connection behavior. Further, three dimensional nonlinear finite element analyses were conducted for each test specimen to demonstrate the in-depth behavior of the connection. Finally, a design equation for the proposed connection was proposed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.