Abstract

The structural design of PEM fuel cell is crucial to improving its power density, and the cell structure largely depends on the bipolar plate (BP). This study compares the conventional single-cell structure and double-cell structure through three-dimensional (3D) large-scale (cell area: 312 cm2) full-morphology simulation. As for the double-cell structure, the channels are arranged in a dislocation manner and there is one cooling flow field per two cells. For the structure of the BP, we also fully considered the realistic morphology of distribution area and the coolant flow. It is found that the heat dissipation effect of double-cell structure is worse but the performance is very close compared to single-cell structure. Moreover, its volumetric power density is significantly improved (∼ 20%) due to the reduction in height. It is also found that increasing the velocity of coolant in the double-cell structure increases the performance first and then decreases.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.