Abstract

This study aimed to understand the ability of fixed-bearing posterior cruciate ligament (PCL)-retaining implants to maintain functionality of the PCL in vivo. To achieve this, elongation of the PCL was examined in six subjects with good clinical and functional outcomes using 3D kinematics reconstructed from video-fluoroscopy, together with multibody modelling of the knee. Here, length-change patterns of the ligament bundles were tracked throughout complete cycles of level walking and stair descent. Throughout both activities, elongation of the anterolateral bundle exhibited a flexion-dependent pattern with more stretching during swing than stance phase (e.g., at 40° flexion, anterolateral bundle experienced 3.9% strain during stance and 9.1% during swing phase of stair descent). The posteromedial bundle remained shorter than its reference length (defined at heel strike of the level gait cycle) during both activities. Compared with loading patterns of the healthy ligament, postoperative elongation patterns indicate a slackening of the ligament at early flexion followed by peak ligament lengths at considerably smaller flexion angles. The reported data provide a novel insight into in vivo PCL function during activities of daily living that has not been captured previously. The findings support previous investigations reporting difficulties in achieving a balanced tension in the retained PCL.

Highlights

  • Posterior cruciate retaining total knee arthroplasty (PCR-TKA) has been advocated as a surgical advancement to better restore joint function

  • Several biomechanical studies suggest that femoral rollback, knee kinematics, and posterior cruciate ligament (PCL) loading is largely variable after PCR-TKA [2,4,10,11,12]

  • It has been proposed that abnormal function of the retained PCL may be responsible for variabilities observed in postoperative kinematics [2,15,16]

Read more

Summary

Introduction

Posterior cruciate retaining total knee arthroplasty (PCR-TKA) has been advocated as a surgical advancement to better restore joint function. The retained posterior cruciate ligament (PCL) is thought to assist femoral rollback with knee flexion, which can increase the moment arm of the knee extensor muscles and increase the knee range of motion (ROM) [1,2,3,4]. Several biomechanical studies suggest that femoral rollback, knee kinematics, and PCL loading is largely variable after PCR-TKA [2,4,10,11,12]. It has been proposed that abnormal function of the retained PCL may be responsible for variabilities observed in postoperative kinematics [2,15,16]

Objectives
Methods
Findings
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.