Abstract

This study proposes an accurate vessel segmentation method using an elliptic-model-guided dynamic programming algorithm to find the shortest path in a two-dimensional matrix. The elliptic model increases the algorithm’s resistance to noise around the vessel boundaries. To test the system reliability and accuracy, we use phantom images with added uniformly distributed noise to get different signal-to-noise ratios. In addition, the optimal parameter values are determined via a phantom study. We further apply this method to detect the boundaries of the common carotid artery (CCA) in real magnetic resonance imaging (MRI) sequences without contrast agent injection. Manual tracings of the CCA boundaries are performed by well-trained experts as the gold standard. Comparisons between the manual tracings and automated results are made on 8 MRI sequences (400 total images). The average unsigned error rate is 3.6 % (standard deviation = 2.4 %). The results demonstrate that the proposed method is qualitatively better than traditional dynamic programming for vessel boundary detection on MRI sequences without contrast agent injection.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.