Abstract
Background: Unlike conventional hemodialysis treatments, which rely almost solely on diffusion-related mechanisms for solute removal, hemodiafiltration (HDF) allows more efficient removal of higher molecular weight toxins due to convective transport mechanisms. To facilitate the removal of these toxins in HDF treatment modalities, dialyzers with highly efficient high-flux membranes are necessary. This study assessed the large uremic toxin removal ability of a high-flux dialyzer (FX CorDiax 60) specifically designed to facilitate convective therapies compared with a standard high-flux dialyzer (FX 60). Methods: In an open, randomized, cross-over, single-center, controlled, prospective clinical study, 30 adult chronic hemodialysis patients were treated by post-dilution online HDF with the FX 60 or the FX CorDiax 60 dialyzer. All other dialysis parameters were kept constant in both study arms. The reduction rate (RR) of blood urea nitrogen, phosphate, β<sub>2</sub>-microglobulin (β<sub>2</sub>-m), myoglobin, prolactin, α<sub>1</sub>-microglobulin, α<sub>1</sub>-acid glycoprotein, albumin and total protein as well as the elimination into dialysate was intraindividually compared for the two dialyzer types. Results: For FX CorDiax 60 versus FX 60, the RR was significantly higher for blood urea nitrogen (86.23 ± 4.14 vs. 84.89 ± 4.59%, p = 0.015), β<sub>2</sub>-m (84.67 ± 3.79 vs. 81.30 ± 4.82%, p < 0.0001), myoglobin (75.23 ± 10.48 vs. 58.60 ± 12.1%, p < 0.0001), prolactin (72.96 ± 9.68 vs. 56.91 ± 13.01%, p < 0.0001) and α<sub>1</sub>-microglobulin (20.89 ± 18.27 vs. 13.60 ± 12.50%, p = 0.016). There were no significant differences in the RR for phosphate, α<sub>1</sub>-acid glycoprotein, albumin and total protein. Mass removal was significantly higher with the FX CorDiax 60 than with the FX 60 for β<sub>2</sub>-m (0.26 ± 0.09 vs. 0.24 ± 0.09 g, p = 0.0006), myoglobin (1.83 ± 0.89 vs. 1.51 ± 0.76 mg, p = 0.0017), prolactin (0.17 ± 0.13 vs. 0.14 ± 0.08 mg, p = 0.02) and albumin (4.25 ± 3.49 vs. 3.01 ± 2.37 g, p = 0.03). Conclusions: This study demonstrates that treating patients with an FX CorDiax 60 instead of an FX 60 dialyzer in post-dilution HDF mode significantly increases the elimination of middle molecules.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.