Abstract

By using standardized Waveforms C and D, this study explored the lightning strike protection (LSP) effectiveness of nickel coated carbon fiber nonwoven veils (Ni-CFNVs) on protecting the carbon fiber composite structures in Zone 2 (aircraft lightning zoning). The post-lightning damage was evaluated by visual inspection, ultrasonic scan and residual strength test. Results showed that the Ni-CFNV of 70 g/m2 eliminated lightning strike damage inflicted by both waveforms and it even performed better than the commercial expanded copper foil of 73 g/m2. Therefore, the Ni-CFNV will be a promising alternative to metal mesh for eliminating lightning strike damage to the structures in Zone 2. The remarkable LSP effectiveness of Ni-CFNV can be explained by its integration of high electrical conductivity of Ni-coating and prominent ablation resistance of carbon fiber. The experiments indicate that not only the electrical conductivity, but also the ablation resistance of LSP layer greatly influences the LSP effectiveness.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.