Abstract

The accuracy of the resonant frequency servo loop is a major concern for high-performance operation of a resonant fiber optic gyro. This is usually resolved by adopting the central frequency of the laser source to track the resonance of the optical fiber ring resonator in one direction. However, the drift of the resonant frequency arising from resonator temperature fluctuation must be eliminated to maintain this accuracy. The traditional proportional integral (PI) frequency servo loop cannot address this issue very well. For instance, a bias error as large as tens or even hundreds of degrees/hour has been observed at the demodulated output of a resonant frequency servo loop. In this paper, we propose a method to eliminate this bias error by adding a double integral term in the traditional PI-based resonant frequency servo loop. We demonstrate that the double integral term can precisely track the linear resonant frequency drift, evidenced by our experimentally achieved close-to-zero bias error of -0.0009 deg/h at the demodulated output of the resonant frequency servo loop.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.