In this study three conventional bipolar linear microcircuits, the LM101A operational amplifier, the LM124 quad operational amplifier, and the LM139 quad voltage comparator, were irradiated at high dose rate, elevated temperature and the results compared to low dose rate, room temperature response. While the high dose rate degradation at elevated temperature was greater than the degradation at room temperature, it was not as great as the degradation at low dose rate. Therefore, a hardness assurance test using elevated temperature irradiation at higher dose rates, designed to bound the very low dose rate response, will probably have to include overtest.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.