Abstract

We report 2 cases of postoperative intraocular pressure (IOP) elevation in secondary piggyback intraocular lens (IOL) implantation without history of glaucoma or ocular hypertension. A 74-year-old woman with myopic pseudophakia and a 68-year-old man with hyperopic pseudophakia received secondary piggyback AcrySof IOL implantation in their left eyes. In both patients, the left IOP gradually increased and sustained around 30 mm Hg for about 1 year. In the first, IOP continued elevating despite topical and systemic medications. There was an episode of pupillary block in the second. Gonioscopically, heavier trabecular meshwork pigmentation in their left eyes was observed. Because of this, the 2 IOLs implanted were removed and replaced by an adequate IOL and trabeculotomy was performed in the former. The AcrySof IOL has a truncated optic edge, which increases the risk for chafing the iris, resulting in pigment dispersion syndrome; thus, it would be a poor choice for a sulcus-placed piggyback implantation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.