Abstract

Cardiac injury persistence after aneurysmal subarachnoid hemorrhage (aSAH) is not well described. We hypothesized that post-aSAH cardiac injury, detected by elevated cardiac troponin I (cTnI), is related to aSAH severity and associated with electrocardiographic and structural echocardiographic abnormalities that are persistent. Prospective longitudinal study was conducted of patients with aSAH with Fisher grade >or=2 and/or Hunt/Hess grade >or=3. Serum cTnI was collected on Days 1 to 5; cohort dichotomized into peak cTnI >or=0.3 ng/mL (elevated) or cTnI <0.3 ng/mL. Relationships among cTnI and aSAH severity, 12-lead electrocardiography early (<or=4 days) and late (>or=7 days), Holter monitoring on Days 1 to 5, and transthoracic echocardiogram (left ventricular ejection fraction and regional wall motion abnormalities) early (Days 0 to 5) and late (Days 5 to 12) were evaluated. Of 204 subjects, 31% had cTnI >or=0.3 ng/mL. cTnI >or=0.3 ng/mL was incrementally related to aSAH severity by admission symptoms (Hunt/Hess P=0.001) and blood load (Fisher P=0.028). More patients with cTnI >or=0.3 ng/mL had prolonged QTc on early (63% versus 30%, P<0.0001) and late electrocardiography (24% versus 7%, P=0.024). On Holter monitoring, more patients with cTnI >or=0.3 ng/mL had ventricular tachycardia/fibrillation (22% versus 9%, P=0.018) but not atrial fibrillation/flutter (P=0.241). Cardiac troponin I >or=0.3 ng/mL was associated with both early ejection fraction <50% (44% versus 5%, P<0.0001) and regional wall motion abnormalities (44% versus 4%, P<0.0001). Regional wall motion abnormalities predominated in basal and midventricular segments and persisted to some degree in 73% of patients affected, whereas ejection fraction <50% persisted in 59% of patients affected. Cardiac injury is incrementally worse with increasing aSAH severity and associated with persistent QTc prolongation and ventricular arrhythmias. Regional wall motion abnormalities and depressed ejection fraction persist to some degree in the majority of those affected.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.