Abstract

The membrane voltage transients in response to constant intracellular current steps were analyzed in cat spinal α-motoneurons, using an equivalent cylinder model extended to include spatial non-uniformity in membrane resistivity. The main hypothesis was that the soma membrane resistivity did not differ significantly from the dendritic membrane resistivity. Evidence was found that the uniform-resistance cylinder model cannot be applied to motoneurons on the basis of inconsistencies in calculations of electrotonic length. Assuming a constant membrane capacitance, the membrane resistivity of the dendrites was found to be 500 times that of the soma. We conclude that there is a considerable difference in the membrane resistivity between the soma and dendrites of motoneurons, and that uniform-resistance models should not be applied to spinal α-motoneurons.