Abstract
This paper is about an electro-thermal model to estimate the semiconductors junction temperature of bidirectional quasi Z-source inverter. Firstly, three types of averaged loss models are presented and compared. In the presented model the impact of the output current waveforms on the loss calculation is considered. Then, based on the instantaneous power loss and developed thermal model, junction temperatures of power devices are estimated. Finally, this paper discusses the factor that influences the junction temperatures: output frequency. It was found that extended model C can be directly presented the temperature peak value and fluctuation amplitude in faster simulation speed. Good agreement between model B and model C. Simulation results are shown to verify the operation and theoretical analysis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.