Abstract

AC electrothermal (ET) flow is inevitable for microfluidic systems dissipating electric energy in a conducting medium. Therefore, many practical applications of biomicrofluidics are prone to ET flow. Here, a series of observations are reported on ET flow in a microfluidic chamber that houses three electrode pairs. The observations indicate that the variations in liquid conductivity and channel height critically impact the structure and magnitude of the flow field. Observations indicate that after a critical conductivity a global ET flow is present in the chamber, while at lower conductivities a vortex is present at every electrode edge. In addition, no ET flow is observed when the chamber height is kept below a critical value at physiological conductivity (∼1.5 S/m). The experimental observations are compared with the numerical simulations of ET flow. The validity of the assumptions made in the current AC ET flow theory is also discussed in the light of the experimental data. The observations can be critical while designing microfluidic systems that involve power dissipation in conductive fluids.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call