Abstract
In this paper the analysis of the influence of C60 fullerenes on flow electrification of mineral insulating oil during aging is presented. Three sets of samples, one fresh and two aged for 24 h and 96 h were tested for their electrification properties using an improved version of a spinning disk system. The relations between C60 concentration and electrification current were determined for different rotational velocities. It is shown, that C60 may significantly reduce or increase the electrification current in mineral oil, depending on fullerenes concentration. The possible causes of observed behavior are analyzed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Dielectrics and Electrical Insulation
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.