The measurement signal from the inner flush-mounted electrostatic sensor includes both induced charge signal and transferred charge signal. The extraction of induced charge signal from the mixed signals is of great significance to the solid phase velocity measurement. In this paper, a method of extracting induced charge signal based on the waveform characteristic in time domain is proposed. In the calibration experiment of the belt-style electrostatic velocity measurement rig, the mean absolute percentage error and the mean relative standard deviation (1.30%/1.01%) are lower than the direct cross-correlation method (4.81%/5.71%) and the Empirical Mode Decomposition (EMD-based) method (2.55%/2.38%), moreover, the average signal-to-noise ratio (SNR) of the proposed method is the greatest. In the experiment of gas-solid two-phase flow rig, the average correlation coefficient and the mean relative standard deviation are 0.77 and 2.46%, which are better than the direct cross-correlation (0.48/2.87%) and the Discrete Wavelet Transform (DWT) (0.74/2.69%).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.